1st Region Revolution in Thermal Insulation: The Way to Use Energy Correctly DOLPHINFIX BORPER 1810 ISI
21.11.2025
☀️ Revolution in Thermal Insulation: BORPER 1810 Thermal Insulation Plaster for Zone 1
In accordance with Turkey's climatic conditions and energy efficiency targets, the Ministry of Environment, Urbanization and Climate Change has revised the exterior thermal insulation values of buildings. As of 2025, 6 distinct zones have been defined based on geographical and altitude data at the province and even district level.
According to this new regulation, in Thermal Value Zone 1, which has relatively milder climates such as the coastal strips of the Mediterranean and the Aegean, the highest wall Thermal Conductivity Coefficient (U) value required for new buildings has been determined as 0.70 W/m²K.
- Zone Thermal Value Target: U ≤ 0.70 W/m²K
As you emphasize, it is of vital importance to maximize energy efficiency while protecting the health of the building and its occupants. Exactly at this point, DOLPHINFIX BORPER 1810 thermal insulation plaster comes into play, standing out with its domestic production and natural structure.
🌊 Solution Specific to Zone 1: Complete Thermal Insulation with BORPER ISI
BORPER 1810 thermal insulation plaster not only provides superior thermal insulation; it also offers a breathable, seamless, and high fire-safety system that remains 100% efficient throughout the building's lifespan.
✅ Standout Features of BORPER ISI:
Superior Thermal Insulation and Energy Efficiency: BORPER PLASTER's low thermal conductivity coefficient (λ = 0.081 W/mK) easily achieves the U ≤ 0.70 W/m²K value required for Zone 1.
Class A1 Fire Safety: Our product provides Class A1 fire insulation, is non-combustible, and does not emit toxic gases during a fire. This means the highest level of protection for your life and property safety.
Effective Sound Insulation: It has strong sound insulation properties that create a peaceful environment in your living spaces by absorbing noise coming from outside the building.
Breathable Insulation: It preserves the natural moisture balance of the structure, prevents the formation of moisture and mold, and offers healthy living spaces. With its BREATHABLE THERMAL INSULATION feature, it does not let dampness pass.
Structure That Does Not Create Thermal Bridges: Thanks to its SEAMLESS THERMAL INSULATION structure, it ensures integrity on the building surface with its THERMAL BRIDGE-FREE INSULATION PLASTER feature that prevents heat loss.
Long-Lasting Investment: Designed as a PRODUCT PROVIDING THERMAL INSULATION FOR THE LIFETIME OF THE BUILDING. It maintains its initial insulation performance even years later.
📍 Some of the Provinces and Districts Located in Zone 1:
BORPER PLASTER solutions are ideal for all buildings in these regions. Below are some of the provinces and districts included in Zone 1:
Adana: Seyhan, Yüreğir, Karaisalı, Kozan, İmamoğlu, Aladağ, Sarıçam, Çukurova, Yumurtalık
Antalya: Merkez, Akseki, Alanya, Finike, Gazipaşa, Kumluca, Manavgat, Serik, Kemer, Aksu, Döşemealtı, Kepez, Konyaaltı, Muratpaşa, Kale (Demre)
Muğla: Bodrum, Datça, Marmaris, Milas, Dalaman
Others: Dörtyol, İskenderun, Samandağ (Hatay); Mut (Mersin)
⚙️ Application Scenarios and Performance Analysis
BORPER 1810 thermal plaster easily ensures reaching the Zone 1 target even on different wall types.
- Application Over BIMS Wall (Interior and Exterior)
When BORPER 1810 thermal application is made at a thickness of 2 cm on the exterior and 2 cm on the interior over a 15 cm BIMS wall, the total Thermal Conductivity Coefficient (U) value of the wall is calculated as 0.67 W/m²K. This value more than meets the Zone 1 requirement of 0.70 W/m²K.
Wall Components (Over 15 cm BIMS) | Thickness d (cm) | Thermal Conductivity λ (W/mK) | Thermal Resistance R=d/λ (m²K/W)
Outdoor Environment + Plasters (Exterior) | 2 | 0.081 | 0.247
BIMS Wall | 15 | 0.180 | 0.830
Plasters (Interior) + Indoor Environment | 2 | 0.081 | 0.247
Total Thermal Resistance ΣR (M²K/W) | – | – | 1.494
Total U Value (1/ΣR) | – | – | 0.67 W/m²K
2. Application Over AAC (GAZBETON) Wall (Interior and Exterior)
When BORPER 1810 thermal application is made at a thickness of 2 cm on the exterior and 1 cm on the interior over a 15 cm AAC (GAZBETON) wall, the total Thermal Conductivity Coefficient (U) value of the wall is calculated as 0.59 W/m²K. This value exceeds the Zone 1 target with even higher performance compared to BIMS.
Wall Components (Over 15 cm AAC) | Thickness d (cm) | Thermal Conductivity λ (W/mK) | Thermal Resistance R=d/λ (m²K/W)
Outdoor Environment + Plasters (Exterior) | 2 | 0.081 | 0.247
AAC Wall | 15 | 0.130 | 1.154
Plasters (Interior) + Indoor Environment | 1 | 0.081 | 0.123
Total Thermal Resistance ΣR (M²K/W) | – | – | 1.664
Total U Value (1/ΣR) | – | – | 0.59 W/m²K
Complete Insulation with BORPER 1810 Thermal: Interior and Exterior
The use of BORPER 1810 Thermal as an INTERIOR AND EXTERIOR THERMAL INSULATION PLASTER maximizes the energy efficiency and health of your structure by insulating not only facades but also areas that may form thermal bridges, such as ceilings and floors.
- Exterior: An aesthetic and protective layer is created with BORPER PLASTER (at appropriate thickness), primer, and D-THERM -170 DTDS - DECORATIVE topcoat.
- Interior: Healthy, breathable, and fully insulated interiors are obtained by applying BORPER 1810 Thermal over the wall (BIMS/AAC), followed by satin finish and paint.
BORPER thermal plaster offers THERMAL INSULATION, SOUND INSULATION, and FIRE INSULATION in a single product for your structure, making it the most professional choice for healthy living and energy efficiency.