Region 2 Thermal Insulation: Insulation Solution Alternative to Classical External Thermal Insulation Composite System (ETICS)
21.11.2025
🌬️ REVOLUTION IN THERMAL INSULATION Solution for Region 2: BORPER 1810 Thermal Insulation Plaster
Energy efficiency standards in Türkiye are rising day by day. The new Thermal Value zones determined by the Ministry of Environment, Urbanization and Climate Change for the year 2025 raise the performance bar for our buildings. The 2nd Thermal Value Zone covers a vast geography experiencing transitions between temperate and continental climates, mandating the highest required Thermal Conductivity Coefficient (U) value for walls as 0.60 W/m²K.
2nd Region Thermal Value Target: $U \le 0.60 \, W/m^2K$
Under these demanding conditions, for those seeking an insulation solution alternative to traditional exterior insulation finishing systems (EIFS), DOLPHINFIX BORPER 1810 thermal insulation plaster delivers performance and comfort that exceed expectations. While informing your customers, we commit not only to energy savings but also to a healthy and safe living space.
🏡 Healthy and Economical Living Spaces with BORPER PLASTER
BORPER 1810 THERMAL is not just a thermal insulation plaster, but a comprehensive INSULATION PLASTER system that adds value to the lifespan of your building.
🔥 A New Era in Safety, Comfort, and Savings
BORPER THERMAL completely eliminates all the drawbacks that your customers do not want when having thermal insulation done:
Customer Concern (What Should Not Exist) | BORPER 1810 THERMAL Solution | Keywords
Paying high utility bills | Minimizes energy consumption with superior thermal insulation. | THERMAL INSULATION
Condensation, mold, and wall darkening | Expels moisture and prevents condensation with its BREATHABLE THERMAL INSULATION feature. | BREATHABLE THERMAL INSULATION
City noise | Increases indoor peace by offering strong SOUND INSULATION contribution. | SOUND INSULATION
Thermal bridges and loss of efficiency | Guarantees THERMAL BRIDGE-FREE INSULATION PLASTER with SEAMLESS THERMAL INSULATION application. | SEAMLESS THERMAL INSULATION
Fire risk and toxic gases | Provides CLASS A1 FIRE INSULATION and does not emit toxic gases in the event of a fire. | FIRE INSULATION
Short lifespan and renovation cost | It is a PRODUCT THAT PROVIDES THERMAL INSULATION FOR THE LIFETIME OF THE BUILDING. | EXTERIOR THERMAL INSULATION
BORPER 1810 THERMAL, with its naturalness, domestic production, and eco-friendly thermal insulation plaster feature, cares not only for the building but also for the health and property safety of its occupants. This NATURAL THERMAL INSULATION PLASTER provides the same efficiency year-round by keeping the interior cool in summer and warm in winter under the changing weather conditions of the 2nd Region.
📍 Some of the Provinces and Districts Falling into the 2nd Region:
A large part of the Southeast such as Gaziantep, Şanlıurfa, Mardin, Batman, Siirt, Adıyaman, Kilis, the center of Kahramanmaraş, certain districts of Mersin and Hatay, the centers of İzmir and Manisa, and the transition zones of Aydın and Denizli are within the scope of Region 2. BORPER PLASTER is the most ideal TERMINOLOGY THERMAL INSULATION PLASTER for your projects in these provinces (Adıyaman Center, İzmir Center, Gaziantep Center, Mersin Center, Hatay Center, Kahramanmaraş Center, etc.).
🔬 Technical Superiority: Minimum Thicknesses for Region 2
Thanks to the low thermal conductivity value of BORPER 1810 THERMAL ($\lambda = 0,081 \, W/mK$), the $U \le 0,60 \, W/m^2K$ target of Region 2 is achieved with minimum thicknesses.
1. Application Over AAC (Autoclaved Aerated Concrete) Wall (Maximum Efficiency)
When BORPER 1810 THERMAL is applied at a thickness of 2.5 cm on the exterior and 1.5 cm on the interior over a 15 cm AAC wall, the total U value of the wall is calculated as 0.55 W/m²K. This value more than meets the Region 2 requirement.
Wall Components (Over 15 cm AAC) | Thickness d (cm) | Thermal Resistance R=d/λ (m²K/W)
Outdoor Environment + BORPER PLASTER (2.5 cm) | 2.5 | 0.309
AAC Wall | 15 | 1.154
BORPER PLASTER (Interior 1.5 cm) + Indoor Environment | 1.5 | 0.185
Total U Value | – | 0.55 W/m²K
2. Application Over BIMS Wall
When BORPER 1810 THERMAL is applied at a thickness of 4 cm on the exterior and 2 cm on the interior over a 15 cm BIMS wall, the total U value of the wall is calculated as 0.57 W/m²K. This combination also successfully satisfies the $U \le 0,60 \, W/m^2K$ condition.
Complete Insulation System: Internal Heat Recovery
Using BORPER 1810 THERMAL not only on the exterior facade but also as an INTERIOR AND EXTERIOR THERMAL INSULATION PLASTER indoors (walls, ceilings, floor screed) ensures full efficiency in energy efficiency. The thermal insulation plaster application performed from the interior retains the heat inside during winter, allowing the interior plaster and wall to heat up. As a result, interior surfaces warm up and directly contribute to the room temperature by returning the heat, making this a most professional choice.
Prepare your buildings for the future in Region 2 with BORPER 1810 Thermal Insulation Plaster, and experience comfort and savings together!