Wärmedämmung für Zone 2: Dämmlösung als Alternative zur klassischen WDV-System-Technik
21.11.2025
🌬️ REVOLUTION IN THERMAL INSULATION Solution for Region 2: BORPER 1810 Thermal Insulation Plaster
Energy efficiency standards in Turkey are rising day by day. The new Thermal Value zones determined by the Ministry of Environment, Urbanization and Climate Change for the year 2025 are raising the performance bar of our buildings. The 2nd Thermal Value Zone covers a wide geography experiencing temperate to continental climate transitions, making the highest required Thermal Transmittance Coefficient (U) value for walls mandatory as 0,60 W/m²K.
Region 2 Thermal Value Target: $U \le 0,60 \, W/m^2K$
Under these demanding conditions, for those looking for an alternative insulation solution to traditional external thermal insulation composite systems (ETICS), DOLPHINFIX BORPER 1810 thermal insulation plaster offers performance and comfort that exceed expectations. While informing your customers, we commit not only to energy savings but also to a healthy and safe living space.
🏡 Healthy and Economic Living Spaces with BORPER PLASTER
BORPER 1810 THERMAL is not just a thermal insulation plaster, but a comprehensive INSULATION PLASTER system that adds value to the lifespan of your building.
🔥 A New Era in Safety, Comfort, and Savings
When applying thermal insulation, BORPER THERMAL completely eliminates all the negative aspects that your customers do not want:
Customer Concern (What Should Not Be) | BORPER 1810 THERMAL Solution | Keywords
Paying high bills | Minimizes energy consumption with superior thermal insulation. | THERMAL INSULATION
Condensation, mold, and wall darkening | Expels moisture and prevents condensation with its BREATHABLE THERMAL INSULATION feature. | BREATHABLE THERMAL INSULATION
City noise | Increases indoor peace by offering strong SOUND INSULATION contribution. | SOUND INSULATION
Thermal bridges and loss of efficiency | Guarantees an INSULATION PLASTER THAT CREATES NO THERMAL BRIDGES with SEAMLESS THERMAL INSULATION application. | SEAMLESS THERMAL INSULATION
Fire risk and toxic gases | Provides CLASS A1 FIRE INSULATION and does not emit toxic gases in the event of a fire. | FIRE INSULATION
Short lifespan and renovation cost | It is a PRODUCT THAT PROVIDES THERMAL INSULATION FOR THE LIFETIME OF THE BUILDING. | EXTERIOR THERMAL INSULATION
BORPER 1810 THERMAL, with its naturalness, domestic production, and eco-friendly thermal insulation plaster feature, considers not only the building but also the health and property safety of those living inside. This NATURAL THERMAL INSULATION PLASTER provides the same efficiency year-round by keeping it cool in summer and warm in winter under the changing weather conditions of Region 2.
📍 Some of the Provinces and Districts Falling in Region 2:
A large part of the Southeast such as Gaziantep, Şanlıurfa, Mardin, Batman, Siirt, Adıyaman, Kilis, the center of Kahramanmaraş, some districts of Mersin and Hatay, the centers of İzmir and Manisa, and the transition zones of Aydın and Denizli are within the scope of Region 2. BORPER PLASTER is the most ideal TERMINOLOGY THERMAL INSULATION PLASTER for your projects in these provinces (Adıyaman Center, İzmir Center, Gaziantep Center, Mersin Center, Hatay Center, Kahramanmaraş Center, etc.).
🔬 Technical Superiority: Minimum Thicknesses for Region 2
Thanks to the low thermal conductivity value of BORPER 1810 THERMAL ($\lambda = 0,081 \, W/mK$), the $U \le 0,60 \, W/m^2K$ target of Region 2 is achieved with minimum thicknesses.
1. Application on AERATED CONCRETE Wall (Maximum Efficiency)
When BORPER 1810 THERMAL is applied at a thickness of 2,5 cm on the exterior and 1,5 cm on the interior on a 15 cm aerated concrete wall, the total U value of the wall is calculated as 0,55 W/m²K. This value more than meets the Region 2 requirement.
Wall Components (On 15 cm AERATED CONCRETE) | Thickness d (cm) | Thermal Resistance R=d/λ (m²K/W)
Outdoor Environment + BORPER PLASTER (2,5 cm) | 2,5 | 0,309
AAC (GAZBETON) Wall | 15 | 1,154
BORPER PLASTER (Interior 1,5 cm) + Indoor Environment | 1,5 | 0,185
Total U Value | – | 0,55 W/m²K
2. Application on BIMS Wall
When BORPER 1810 THERMAL is applied at a thickness of 4 cm on the exterior and 2 cm on the interior on a 15 cm BIMS wall, the total U value of the wall is calculated as 0,57 W/m²K. This combination also successfully meets the $U \le 0,60 \, W/m^2K$ condition.
Complete Insulation System: Internal Heat Recovery
Using BORPER 1810 THERMAL not only on the exterior facade but also internally (on walls, ceilings, floor screed) as an INTERIOR AND EXTERIOR THERMAL INSULATION PLASTER ensures complete efficiency in energy efficiency. Thermal insulation plaster application made from the interior preserves the heat inside during winter and allows the interior plaster and wall to heat up. Thus, interior surfaces warm up and directly contribute to room temperature by reflecting heat back, which is the most professional choice.
Prepare your buildings for the future in Region 2 with BORPER 1810 Thermal Insulation Plaster, and experience comfort and savings together!