🌐 English ▾
📞 Customer Line 24/7539 303 00 72
🌐 English ▾
Home›Blog›The Secret of Flawless Floors in Hospitals and Foo...

The Secret of Flawless Floors in Hospitals and Food Facilities: MicroFloor A 1001 MFA

23.05.2026 The Secret of Flawless Floors in Hospitals and Food Facilities: MicroFloor A 1001 MFA

Dolphinfix is a strong brand offering professional solutions in the fields of construction chemicals, concrete solutions, historical artifact repair mortars, and heat, water, and sound insulation systems. With flexible sales options from 1 kg to truck-based shipments, a wide product range, and fast supply advantages, it provides reliable solutions from individual applications to large-scale construction site and industrial projects.

Health and food sectors are two critical areas that directly affect human health and are therefore strictly monitored by international standards. In spaces such as hospitals, operating rooms, laboratories, food production facilities, and pharmaceutical warehouses, cleanliness and hygiene are not just a preference but a legal necessity. In such areas, every detail from architectural design to material selection is planned to prevent the formation of germs, bacteria, and mold. One of the most vital links in the hygiene chain is the floor beneath our feet.

In sterile areas, floors must be smooth, non-porous, easy to clean, and resistant to chemicals. PVC, linoleum, or special sports floor coverings are usually preferred as floor coverings. However, the performance of these top-layer covering materials depends entirely on the quality of the screed applied underneath. If the underlying screed layer is wavy, rough, or most importantly, contains organic matter, the system collapses no matter how high quality the top covering material is.

This is precisely where the innovative technology-driven MicroFloor A 1001 MFA Special Self-Leveling Screed (1-5 mm) developed by Dolphinfix comes into play. In this article, we will examine flooring standards in health and food facilities, the hidden dangers of traditional screeds in sterile areas, and why MicroFloor A 1001 MFA has become an industry standard in these areas with all its technical details.

Flooring Standards and Hygiene Relationship in the Health and Food Sector

Hospitals and food factories are the most favorable environments for the propagation of microorganisms. There are certain international standards that floors must comply with in order to prevent cross-contamination and ensure complete sterilization in these facilities. These standards generally cover the following items:

  • Continuous and Non-Porous Surface: Germs and bacteria breed in microscopic pores, cracks, and joint gaps. It is essential that floors are completely smooth and monolithic.
  • Easy Cleanability and Disinfection: Surfaces must be resistant to aggressive chemical disinfectants, hot water, and continuous washing processes.
  • Condition of Containing No Organic Matter: Materials used in floor layers are expected not to create a food source for bacteria and fungi, meaning they must be completely inorganic.

Traditional floor preparation materials and ordinary self-leveling screeds fall short of meeting these high standards due to some additives they contain. Over time, this leads to a massive hygiene crisis at a microscopic level beneath the floor.

The Hidden Danger in Traditional Screeds: Casein and Protein Additives

Many users and applicators do not know what chemicals are added to ready-mixed self-leveling screeds during production to increase their fluidity. In traditional smart screed formulas, casein (milk protein) or various animal protein-based additives are commonly used to facilitate the flow of the material and extend the workability time.

In a normal residential or office project, this situation may not pose a major problem. However, in areas with high humidity, temperature, and hygiene sensitivity such as hospitals and food facilities, casein-containing screeds create a major risk.

Negative Effects of Casein-Containing Screeds in Sterile Areas

  • Food Source for Bacteria and Mold: Casein is an organic protein. The slightest moisture that can leak into the pores of the screed or water leaking from a capillary crack in the top covering, when combined with casein, creates an excellent breeding ground for bacteria and fungi. An invisible mold and colony of bacteria breeds beneath the floor.
  • Odor Formation: The decay of organic materials beneath the floor over time and exposure to moisture causes chronic and heavy odors to spread into the environment. In areas such as hospitals where ventilation operates on a closed circuit, this situation is unacceptable.
  • Blistering and Decay of the Top Covering: Microorganisms breeding beneath the floor and gas emissions destroy the chemical structure of the top PVC or linoleum adhesive. Blistering, bubbling, opening at joints, and tearing occur in the covering.

MicroFloor A 1001 MFA definitely does not contain casein or any other type of protein. Since it is completely modified with inorganic and synthetic polymers, it reduces biological risks to zero in sterile areas.

What is MicroFloor A 1001 MFA and What Are Its Prominent Features?

MicroFloor A 1001 MFA is a cement-based floor leveling screed that can be applied manually or by pump, consisting of special cements, qualified fillers, synthetic binders, and new-generation eco-friendly superplasticizer chemical additives. It is specially formulated to be applied in millimetric thicknesses ranging from 1 mm to 5 mm in a single coat.

The technical and operational features of the product completely set it apart from ordinary screeds:

  • Does Not Contain Protein and Casein: As mentioned above, it is biologically completely safe. It does not breed bacteria, does not cause odor.
  • Superplasticizer Technology: Thanks to the new-generation eco-friendly superplasticizers it contains, it shows maximum fluidity and spread with a minimum amount of water.
  • Rapid Setting: It becomes walkable in normal weather conditions just 2 to 4 hours after application. This prevents other manufacturing works on construction sites from stopping.
  • Low Shrinkage Feature: It does not shrink or contract while drying. The free shrinkage rate is at an excellent level of 0.04% – 0.06%. Thus, no crack formation is observed on the surface.
  • Excellent Surface Smoothness: It creates a surface texture that is as smooth, flat, and dust-free as a mirror after application.

Technical Specifications and Performance Values of the Product

MicroFloor A 1001 MFA is a high-performance engineering material tested in accordance with international standards (for example, Swedish standards SS 92 35 07 and SS 92 35 19). The nominal values found in the technical data sheet of the product are as follows:

  • Compressive Strength: > 19 N/mm² (High resistance against pressure applied to the floor)
  • Flexural Strength: > 4 N/mm² (Flexibility and crack resistance)
  • Adhesion to Concrete (Bond Strength): > 1.5 N/mm² (Never separates from old concrete)
  • MINTEC Ring Test (Fluidity Value): 145 – 155 mm² (Proof of excellent spread)
  • Pot Life of Ready Material: 15 – 20 Minutes (Fast and practical application window)
  • pH Value: Approximately 11 (Natural protection against microorganism formation thanks to its alkaline structure)
  • Time to Open to Foot Traffic: 2 – 4 Hours

Areas of Use: Where is MicroFloor A 1001 MFA Preferred?

This special leveling screed is used as a floor preparation layer both in new construction projects and in renovation works of existing buildings where floor smoothness and hygiene are critical.

1. Health Sector and Sterile Areas

Hospital operating rooms, intensive care units, patient rooms, corridors, laboratories, dental clinics, dialysis centers, and pharmaceutical production facilities. It creates a flawless bed under the antibacterial PVC or linoleum coverings to be applied on it in these areas.

2. Food Industry and Storage

Meat and dairy processing facilities, bakeries, catering kitchens, cold storage rooms, dry food warehouses, and packaging rooms. It ensures that the floor is completely leveled to prevent water accumulation during cleaning.

3. Commercial and Public Areas

Schools, nurseries, universities, shopping malls, luxury office buildings, and stores exposed to heavy foot traffic. It is ideal for achieving flawless flatness prior to solid or engineered parquet, floating system parquet, carpet, and ceramic tile installations.

Importance of Flawless Floor Preparation Before PVC and Linoleum Covering

PVC and linoleum are the most preferred materials as top coats in health and food facilities. These materials come in rolls and are adhered flush to the floor with special adhesives. The joints are fused and joined with welding cords, thus achieving a completely continuous surface.

However, the biggest feature of these flexible covering materials is that they reflect all imperfections on the subfloor upward. If there is a 1 mm undulation or a small stone particle on the subfloor, that point appears as a bump on the top surface after the PVC is installed. Over time, foot traffic and cleaning machines rub against that bump, causing the covering to puncture at that point.

MicroFloor A 1001 MFA fills capillary pits, cracks, and trowel marks between 1-5 mm with its own fluidity, offering a smooth floor for the covering material. Thus:

  • The amount of PVC/Linoleum adhesive to be consumed drops to a minimum.
  • The adhesive is not absorbed by the screed, adhesion performance increases.
  • The service life of the top covering increases at least twofold, premature wear is prevented.
  • Cleaning machines move smoothly over the floor, hygienic cleaning is facilitated.

Step-by-Step Professional Application Method

To get maximum performance from MicroFloor A 1001 MFA, application steps must be completed fully in accordance with the standards specified in Dolphinfix technical sheets. The application process consists of three main stages:

1. Detailed Surface Preparation

The sub-concrete floor to be applied must definitely be hard, solid, and load-bearing. Dust, loose particles, mortar residues, and cement laitance on the surface must be completely cleaned by mechanical scraping, grinding, or vacuuming methods.

Remaining adhesive residues from old coverings must be removed. If there are oil, grease, or paraffin stains on the floor that would prevent adhesion, these areas must be burned off with a torch or cleaned with special grease cleaners approved by Dolphinfix. It should not be forgotten that a screed application made on a dusty and weak floor will detach from the concrete in a short time.

2. Critical Stage: Priming (Dolphinfix EMC 720 or PAR 721)

Priming is of vital importance for the screed to adhere perfectly to the sub-concrete and to prevent the concrete from absorbing the water in the screed and drying the screed out suddenly after the screed is poured. Primer selection is made according to the structure of the floor:

For Absorbent Surfaces (Normal Concrete and Screeds)

Dolphinfix EMC 720 Absorbent Surfaces Screed Primer should be used. If the floor is very absorbent, the primer is applied diluted with clean water at a ratio of 1:5 for the first coat and 1:3 for the second coat. For solid and standard concrete, a single coat of primer diluted at a ratio of 1:3 is sufficient. The primer should be applied homogeneously with a soft brush or primer pump without creating puddles and left to dry for 2 to 4 hours.

For Glossy and Non-Absorbent Surfaces (Old Tiles, Marble, Exposed Concrete)

If the screed is to be applied over an old ceramic or marble floor, a plain primer cannot hold because the surface is glossy. In this case, Dolphinfix PAR 721 Glossy Surfaces Screed Primer should be applied directly without dilution. This green-colored primer creates a rough texture on the surface, allowing the screed to lock onto the floor. Drying time is 40-60 minutes.

Important Note

During primer application, the floor temperature must be above +10°C, and the relative humidity in the air must be below 70%. Screed should not be poured before the primer is completely dry.

3. Mixing with Correct Ratios

The water ratio of the material must be adjusted millimetrically. Exactly 5.00 liters (at a ratio of 20%) of clean water must be used for one bag (25 kg) of MicroFloor A 1001 MFA.

Water is first placed into a clean mixing bucket, and then the powder material is slowly added. It is mixed homogeneously for at least 2 minutes using a suitable mixing paddle attached to a drill bit, ensuring there are no lumps left inside. Following the mixing process, the material must be applied to the floor within 15-20 minutes. The dry material having been kept in an excessively hot or cold environment prior to application may affect fluidity performance.

4. Spreading the Material and Air Bubble Removal (Spike Roller)

The mixed fluid screed is poured continuously onto the surface whose primer has dried. While the material spreads under its own weight, guidance can be provided with a steel spatula or an adjustable notched trowel to precisely adjust the desired thickness (1-5 mm).

Immediately after the pouring process, the mortar must be run over with a spike roller (pin roller). The spike roller ensures that air bubbles trapped inside the mortar during mixing rise to the surface and burst. If a spike roller is not used, thousands of microscopic air holes (pinholes) remain on the surface after the screed dries, which completely ruins hygiene standards.

Points to Consider During and After Application

  • Temperature Limits: Ambient and floor temperature must be between +5°C and +20°C during application and throughout the first 24 hours afterwards. In very hot weather, the mortar can lose its water quickly.
  • Air Draft and Drying: There must be no direct wind, draft, or cross-draft in the area where the screed is applied for the first 48 hours. Doors and windows must be kept closed. Dehumidifiers, fans, or heaters must definitely not be used to dry the screed quickly. Sudden drying causes the screed to crack and lift at the edges (curling).
  • Expansion Joints: Movement and expansion joints present in the main structure of the building must never be covered with screed. After the screed dries, these joints must be transferred identically to the new surface with a joint cutting machine and filled with suitable polyurethane mastics.

Why Dolphinfix MicroFloor A 1001 MFA?

In flooring projects in the health and food sector, the margin of error is zero. Repairing a screed that breeds bacteria, smells, or lifts from under the PVC covering due to wrong material selection leads to the facility being closed for days and very heavy financial losses.

Dolphinfix MicroFloor A 1001 MFA is a smart investment meeting all requirements of modern flooring engineering. With its casein-free eco-friendly formula, high compressive strength exceeding 19 N/mm², non-cracking structure, and speed allowing pedestrian traffic in as short a time as 2 hours, it both eases the work of applicators and offers property owners hygienic and lifelong floors at international standards. To reduce risk to zero in your projects and get information about technical details, you can always contact the Dolphinfix technical support team.

Contact Us for the Amount of Product You Need!

Dolphinfix offers reliable supply and technical support in construction chemicals, concrete solutions, insulation systems, and special mortar groups, ranging from packaging options starting from 1 kg to pallet, tonnage, and truck-based industrial deliveries. For detailed information and quotes, you can visit www.dolphinfix.com.tr or contact our sales representatives.

📞(0212) 945 00 59

Get a quote for bulk purchases