The Secret to Flawless Floors: What is Self-Leveling Screed, How Is It Applied?
23.05.2026
Dolphinfix is a strong brand offering professional solutions in the fields of construction chemicals, concrete solutions, historical artifact repair mortars, and heat, water, and sound insulation systems. With flexible sales options ranging from 1 kg to truckloads, a wide product range, and the advantage of fast supply, it provides reliable solutions from individual applications to large-scale construction site and industrial projects.
In construction and renovation projects, the most critical factor determining the lifespan and aesthetics of floor covering is the smoothness of the subfloor. Whether it is residential projects or commercial areas exposed to heavy pedestrian and load traffic, uneven, unlevel, and rough floors cause top-layer materials such as parquet, PVC, epoxy, or ceramic to be damaged in a short time.
Modern construction technologies offer an innovative solution that fundamentally solves this problem, lowers labor costs, and saves time: self-leveling screed. In this guide, we will examine self-leveling screed applications, types, application details, which revolutionize floor engineering, and Dolphinfix's technological flooring solutions, the leading brand of the industry, in all details.
What is Self-Leveling Screed?
Self-leveling screed is a floor preparation material composed of special cements, fillers, synthetic polymers, and next-generation superplasticizing chemical additives that increase fluidity, finding its own balance and leveling on the surface it is applied to with the effect of gravity. In the industry, it is also commonly referred to as self-leveling screed or leveling screed by its English equivalent.
Smoothness and leveling, which are tried to be achieved for hours with a screed board and trowel in traditional screed applications, are achieved in a much shorter time, flawlessly, and with millimeter precision thanks to self-leveling screeds. These materials have high fluidity thanks to the special chemicals they contain, but they do not segregate. By leveling by themselves, they perfectly close capillary cracks, surface defects, and elevation differences.
By What Other Names is Self-Leveling Screed Searched?
In floor applications and material supply processes, this product group may appear with different technical or commercial names. Other names frequently used in search engines and on-site language are:
- Self-Leveling Screed
- Mercury Screed
- Smart Screed
- Floor Leveling Screed
- Self-Leveling Screed
- Non-Pumpable / Pumpable Cement-Based Leveling Screed
- Ready-Mix Floor Repair Mortar
Are There Types of Self-Leveling Screeds?
Yes, floor leveling screeds vary according to the intended use, application thickness, the amount of load it will be subjected to, and the binder type. Choosing the right product is the first and most important step for the success of the application. In general, leveling screeds are categorized according to the following criteria:
1. Screed Types According to Thicknesses
Thin-Layer Leveling Screeds (1 – 7 mm)
Generally preferred when there are no very aggressive elevation differences, just to provide surface smoothness and make millimeter-level corrections. MicroFloor A 1001 MFA (1-5 mm) and Dolphinfix 1118 S50 Floor Self 50 (1-7 mm) are among the strongest examples of this category.
Thick-Layer Leveling Screeds (3 – 30 mm)
These are high-strength screeds used in heavily loaded areas, deep floor defects, or to equalize high elevation differences. Dolphinfix MicroFloor A 1002 MFA (3-30 mm) and Dolphinfix 1119 S200 Floor Self 200 (1-20 mm) have been specially developed for deep fills.
2. Screed Types According to Binder Type
Cement-Based Screeds
These are the most commonly used products in the market, with high mechanical strength and moisture resistance, based on cement, aggregate, and polymer.
Calcium Sulfate (Anhydrite) Based Screeds
Generally gypsum-based, preferred because the risk of shrinkage in large areas is very low, but its moisture sensitivity is high.
Why Should Self-Leveling Screed Be Preferred?
The advantages offered by self-leveling screeds compared to traditional leveling methods have made these products a standard in modern construction projects. The reasons for preference can be listed as follows:
- Flawless Smoothness and Leveling: Since it spreads on its own by the force of gravity, it offers surfaces that are independent of human error, at a millimetric level of leveling and mirror-smoothness.
- Fast Hardening and Time Saving: While traditional screeds take weeks to dry, smart screeds are open to pedestrian traffic 2 to 4 hours after application. Within a few days, top-layer coating can be applied on them.
- High Mechanical Strength: Flexural and compressive strengths are much higher compared to standard concrete and screeds. They do not crack, crumble, or dust.
- Low Shrinkage Risk: Thanks to their special formulas, they do not pull during curing, which minimizes crack formation.
- Easy and Ergonomic Application: Since it can be applied both manually and with mortar pumps, very large areas can be covered in a very short time with low labor.
- Eco-Friendly and Health-Friendly Structure: Next-generation eco-friendly leveling screeds (e.g., Dolphinfix MicroFloor series) do not contain casein or protein in their composition. Thus, they do not produce bacteria or odor; they are 100% safe for hospitals, schools, and food facilities.
Where is Self-Leveling Screed Used?
These screeds are used as a floor preparation layer in all interiors where a top-layer coating material (parquet, PVC, etc.) will be directly glued or laid. Main application areas:
- Residential and Commercial Areas: Homes, offices, shopping malls, stores, and showrooms.
- Health and Education Institutions: Hospitals, clinics, laboratories, schools, and universities.
- Industrial and Logistics Facilities: Food production facilities, pharmaceutical warehouses, sterile packaging rooms.
- Sports Facilities: Indoor sports halls, athletic flooring sub-preparations.
- Renovation Projects: In the renovation of old buildings, correcting existing uneven concrete.
Important Note: Self-leveling leveling screeds (excluding special industrial top-layer screeds) should generally not be left as the final floor coating at the final stage. A protective coating (parquet, PVC, carpet, ceramic, etc.) must definitely be applied over it.
Is There a Standard for Self-Leveling Screed?
Yes, technical performance limits of these products are determined by strict rules in European and Turkish standards. In our country, floor leveling compounds and screed materials are subject to the TS EN 13813 (Screed material and floor screeds – Screed material – Properties and requirements) standard.
Within the scope of this standard, parameters such as compressive strength (C), flexural strength (F), wear resistance (A), and bond strength (B) of the products are tested and certified. You must definitely check the compliance of the products you will use in your projects with these standards.
Points to Consider When Choosing Self-Leveling Screed
If you want to proceed with zero errors in your flooring project, you should consider the following criteria when choosing materials:
1. Application Thickness
The elevation difference on the floor and the depth of the pits should be measured thoroughly. If the floor defect does not exceed 5 mm, thin-layer screeds should be chosen; if there are undulations up to 20-30 mm, thick-layer screeds should be chosen.
2. Pedestrian and Load Traffic Intensity
For commercial areas and industrial floors, high-performance products with a compressive strength of >25 N/mm² (E.g.: MicroFloor A 1002 MFA) should be preferred. A strength of >19 N/mm² may be sufficient for residences.
3. Floor Type and Rigidity
The absorbency and smoothness of the subfloor to be applied (tile, gross concrete, etc.) affect the adhesion of the screed. The primer and screed combination suitable for the floor should be chosen.
4. Hygiene and Hygiene Certificates
Screeds to be used in areas such as hospitals, schools, or food businesses must have an organic formula structure that does not contain casein and protein.
5. Drying Time
If there is a time constraint in the project, products that set quickly and allow coating in a short time (24-48 hours) should be chosen.
How Should Self-Leveling Screed Floor Preparation and Application Floor Be?
The success of a self-leveling screed application depends 70% on floor preparation. Even if you use the best screed in the world, cracking and blistering will be inevitable on a weak and unprepared floor.
How Should the Ideal Application Floor Be?
- Solid and Load-Bearing: The underlying concrete floor must be in a rigid structure with high compressive strength, not flaking and shedding.
- Dry and Moisture-Free: The relative humidity in the floor must be below 70%. Newly poured concrete must have completed its curing (at least 28 days).
- Clean and Dust-Free: There should be no foreign substances on the surface that would prevent adhesion.
- Thermal Balance Stabilized: During application, the floor and ambient temperature must be between +5 °C and +35 °C. Application on floors below +10 °C is not recommended.
Step-by-Step Self-Leveling Screed Application Method
To ensure that the application is carried out in accordance with professional and technical standards, the following operational steps must be followed completely:
Step 1: Mechanical Surface Preparation
Before application, all weak layers, cement slurry, old paint, or adhesive residues on the surface to be coated must be removed by mechanical methods (milling, grinding, or shot blasting). All dust must be cleaned with vacuum industrial cleaners. If there are oil or grease stains on the floor, they must be completely cleaned by burning with a blowtorch or using special oil-cleaning chemicals.
Step 2: Proper Priming (Critical Stage)
Priming is a step that must definitely not be skipped to balance the absorbency of the subfloor, prevent air bubbles from rising to the screed surface (pinhole formation), and maximize adhesion (bonding strength). Primer selection according to floor type should be as follows:
For Absorbent Surfaces (Concrete, Aerated Concrete, Gypsum Plaster, Screed)
Dolphinfix EMC 720 Absorbent Surfaces Screed Primer must be used. This single-component, copolymer acrylic-based product prevents cracks caused by rapid water loss. It is applied with a soft brush or roller without causing pooling. On highly absorbent floors, it is applied diluted with water at a ratio of 1:5 for the first coat and 1:3 for the second coat; whereas on solid concrete, a single coat at 1:3 is sufficient. Wait 2-4 hours for it to dry.
For Glossy and Non-Absorbent Surfaces (Ceramic, Tile, Marble, Gross Concrete)
Dolphinfix PAR 721 Glossy Surfaces Screed Primer must be used. This special primer, which is single-component, acrylic-based, water-based, and green in color, creates a great bonding bridge by taking the roughness of glossy surfaces. Before use, it should be mixed homogeneously with a low-speed mixer and applied undiluted at 150-250 grams per m². Drying time is 40-60 minutes.
Step 3: Mixing and Homogenization
Water ratios specified in the product packaging must be followed down to the millimeter. Adding too much water reduces the strength of the screed, leading to cracking and dusting; insufficient water impairs fluidity. Water is first put into a clean bucket, and then the powdered screed is slowly added while mixing with a low-speed (max. 400-600 rpm) mixing paddle for at least 2-4 minutes until a lump-free, homogeneous mixture is obtained.
Step 4: Spreading and Spike Roller Application
The prepared fluid mortar is poured continuously onto the prepared and primed floor. While observing the mortar spreading on its own, the material is guided with the help of a steel trowel or an adjustable notched trowel to adjust the thickness.
The poured material must definitely be rolled over with a spike roller (spiked roller). The spike roller ensures that air bubbles mixed into the mortar are popped and released, thus preventing the formation of small holes (craters) on the floor. The mixed material must be consumed within a maximum of 15-20 minutes.
When Can Application Be Made Onto It After Self-Screed Is Made?
When the top-layer coating (parquet, PVC, etc.) will be made on the screed varies depending on the chemical structure of the selected product, application thickness, ambient temperature, and relative humidity.
- Opening to Pedestrian Traffic: Quality self-leveling screeds (like the Dolphinfix series) reach a hardness that can be walked on 2 to 4 hours after application.
- Top-Layer Coating Time: Generally, while it is necessary to wait 48 – 60 hours in thin layers (1-7 mm), it may be necessary to wait 3 days (72 hours) for complete curing and moisture removal in thicker applications (20-30 mm). High ambient temperature shortens these times, while low temperatures and high humidity lengthen them. Before coating, the floor must be checked with a moisture meter device.
Dolphinfix Self-Leveling Screed Product Family and Technical Comparison
Dolphinfix, the first choice of professionals in floor engineering, produces floor leveling screeds and primers suitable for every purpose and thickness.
Product Name | Application Thickness | Compressive Strength | Flexural Strength | Pedestrian Traffic Time | Coating Application Time | Mixing Water Ratio (for 25 kg) | Consumption (at 1 mm Thickness)
MicroFloor A 1001 MFA (1-5 mm) | 1 – 5 mm | > 19 N/mm² | > 4N/mm² | 2 – 4 Hours | 24 – 48 Hours | 5.00 Liters (20%) | 1.5 kg/m²
MicroFloor A 1002 MFA (3-30 mm) | 3 – 30 mm | > 25N/mm² | > 5N/mm² | 1 – 3 Hours | 1 – 3 Days | 4.37 Liters (17.5%) | 1.5kg/m² (15 kg for 1 cm)
1118 S50 – Floor Self 50 (1-7 mm) | 1 – 7 mm | > 20N/mm² | > 4 N/mm² | 8 – 12 Hours | 48 – 60 Hours | 6.50 Liters (26%) | 1.5kg/m²
1119 S200 – Floor Self 200 (1-20 mm) | 1 – 20 mm | > 25 N/mm² | > 4 N/mm² | 12 – 18 Hours | 48 – 72 Hours | 5.75 Liters (23%) | 1.5 kg/m²
Outstanding Detailed Features of Dolphinfix Products
MicroFloor A 1001 MFA (1-5 mm)
It is a next-generation eco-friendly floor leveling screed containing special cement and superplasticizers. Since it does not contain casein or protein-derived additives in its structure, it is safely preferred in hospitals, food production facilities, and pharmaceutical warehouses. It offers very smooth surface performance and completely eliminates the risk of cracking with its low shrinkage property.
MicroFloor A 1002 MFA (3-30 mm)
It is a performance screed that can be poured both manually and with mortar pumps, allowing high-thickness fills. Thanks to its high compressive strength exceeding the value of 25 N/mm², it is an excellent sub-preparation material for commercial areas, schools, and industrial floors under heavy load. It opens to pedestrian traffic in a very short time such as 1 to 3 hours.
1118 S50 – Floor Self 50 (1-7 mm)
It is a cement-based leveling screed developed for thin applications, having high fluidity and spreading ability. Offering economical and fast application opportunity, this product gives great results especially for correcting unlevel floors before PVC, linoleum, and carpet laying in residential projects. Its pumpable structure maximizes labor speed.
1119 S200 – Floor Self 200 (1-20 mm)
It is a cement-based screed with a rigid structure that can be poured up to 20 mm thickness in a single coat and does not crack. Thanks to its high adhesion performance, it clings perfectly to the subfloor. It is safely used alone or as an under-coating for floor corrections of large indoor spaces, including industrial areas.
Attention Applicators (Important Warnings)
- Never apply products at temperatures below +5°C and above +35°C.
- Do not add external cement, sand, or any other foreign chemical substance to the mixture.
- Protect the floor from direct sunlight, strong wind, frost risk, and rain for the first 48 hours after the screed is poured.
- Slight ventilation can be provided in the room after application, but dehumidifiers or rapid drying fans must definitely not be used for the first two days; otherwise, the screed may lose water suddenly and crack.
- Structural dilatation and movement joints located on the subfloor must definitely be transferred to the new surface and cut in the exact same way after the leveling screed is applied.
Conclusion
In conclusion; a correctly analyzed floor preparation, a Dolphinfix primer chosen appropriately for the floor type (EMC 720 or PAR 721), and a Dolphinfix Self-Leveling Screed composition applied at the correct thickness are the single formula for lifelong, non-cracking, and perfectly level floors in your projects. To reduce the risks on your floors to zero and get professional technical support, you can always consult Dolphinfix engineering solutions.
Contact Us For The Amount of Product You Need!
Dolphinfix offers reliable supply and technical support in construction chemicals, concrete solutions, insulation systems, and special mortar groups, ranging from packaging options starting from 1 kg to pallet, tonnage, and truckload-based industrial deliveries. For detailed information and quotes, you can visit www.dolphinfix.com.tr or contact our sales representatives.
📞(0212) 945 00 59