🌐 English ▾
📞 Customer Line 24/7539 303 00 72
🌐 English ▾
Home›Blog›What is Micro Concrete Technology? Decorative and...

What is Micro Concrete Technology? Decorative and Industrial Flooring Solutions

22.05.2026 What is Micro Concrete Technology? Decorative and Industrial Flooring Solutions

Dolphinfix is a strong brand offering professional solutions in the fields of chemical construction products, concrete solutions, historical artifact restoration mortars, and heat, water, and sound insulation systems. With flexible sales options ranging from 1 kg to truckload shipments, a wide product range, and the advantage of fast supply, it provides reliable solutions from individual applications to large-scale construction site and industrial projects.

1. What is Micro Concrete (Microtopping) Technology?

Micro concrete is an optimized combination of special high-strength cements, qualified mineral fillers with controlled particle size, high-performance liquid or dust polymer binders, and next-generation functional chemical additives that regulate the rheology of the mortar. It is defined as a fluid floor coating mortar that has self-leveling and smoothing capabilities, creating a monolithic (single-piece) structure on the surface where it is applied.

Its difference from traditional gross concrete applications is the high polymer modification in its formulation. Thanks to this modification, the material exhibits high bending and compressive strength even when poured in millimeter-scale cross-sections (4 – 30 mm) and does not react with cracking against shock loads.

By What Names Does Micro Concrete Go in Search Engines and Specifications?

In order to fully respond to users' search intent in the digital world and to accurately analyze architectural technical specifications, it is necessary to know the equivalents of the micro concrete concept in global and sectoral literature. This technology finds correspondence with the following terms in Google search volumes and projects:

• Microtopping

The global literature name in architectural and decorative surface designs.

• Decorative Concrete Coating

System definition that brings the industrial gross concrete appearance into living spaces.

• Self-Leveling Cement-Based Screed

The technical term defining the fluid rheological structure.

• Fluid Micro Concrete

The name expressing the homogeneous flow capability of the aggregate and filler structure.

• Seamless Concrete Floor Coating

Sectoral naming highlighting visual integrity and continuous surface advantage.

2. The Big Screed Trap: What Are the Technical Differences Between Standard Leveling Screed and True Micro Concrete?

One of the most common errors in sectoral applications is presenting standard floor leveling mortars, known in the market as "mercury screed" or "self-leveling screed", as if they were a top-coat decorative micro concrete floor coating. This preference made by falling into the trap of low cost leads to peeling, dusting, flaking, and structural crack crises in floors in the subsequent process. The sharp technical differences between the two materials are as follows:

• Layer Purpose (Top Coat vs. Underlayer)

Standard leveling screeds are underlayer materials produced to provide strength balance and flatness under the final floor coating (ceramic, carpet, parquet, PVC, etc.). The Dolphinfix MicroFloor series, on the other hand, is a final coat floor coating designed aesthetically and mechanically, which can be left completely bare on its own.

• Abrasion and Traffic Resistance

Surface hardness and abrasion resistance of standard screeds are very low; they crumble and dust in a short time when exposed directly to pedestrian or wheel traffic. True micro concretes, thanks to their crystal matrix structure, show high abrasion resistance against friction, impact, and heavy loads.

• Compressive and Bending Strengths

While the compressive strengths of standard leveling screeds generally do not exceed the 15 – 20 N/mm² band, the compressive strength of industrial-type micro concretes such as Dolphinfix MICROFLOOR MB 1004 MFB reaches > 40 N/mm² values, easily bearing even heavy forklift traffic.

• Resistance to Atmospheric Conditions

Ordinary screeds are resistant neither to outdoor conditions, freeze-thaw cycles, nor moisture; they burst in a short time. True micro concretes with certified quality, on the other hand, maintain their stable structure both indoors and outdoors thanks to polymer modifications.

Technical Specification Summary

In summary, you must definitely lay a protective material over standard leveling screeds. Dolphinfix MicroFloor series true micro concretes, however, do not require any additional coating material on top after being poured; they form the surface itself that will be opened directly to traffic.

3. What Are the Dolphinfix MicroFloor Product Family and Technical Performance Criteria?

The approach of "a single product fits all floors" in floor engineering and construction site management is a major mistake from a technical standpoint. The mechanical resistance and elasticity required in a residence's living room cannot be the same as the shock loads, friction coefficients, and cross-section thicknesses of an industrial facility where heavy forklifts operate.

As Dolphinfix, in line with our renewed Technical Data Sheets (TDS), we offer 3 basic system components optimized to fully meet the structural and architectural requirements of your flooring projects:

MICROFLOOR RM 1000 MRM (Floor Repair, Filling, and Rehabilitation Mortar)

It is a high-strength repair mortar that does not undergo shrinkage, designed to prepare the subfloor infrastructure prior to micro concrete. It is used in closing deep holes, filling segregation (honeycomb) voids, eliminating elevation differences, and repairing structural cracks. It can be applied in a single coat from 2 mm up to 100 mm thickness. Its 28-day compressive strength is > 25 N/mm² and its bending strength is > 5 N/mm².

MICROFLOOR MB 1003 MFB (Next-Generation Fluid Decorative Micro Concrete)

It is an architectural top-coat coating mortar specially developed for residences, villas, hotel rooms, lobbies, luxury showrooms, modern offices, restaurants, and cafes. It reflects the aesthetic gross concrete texture seamlessly and monolithically onto the floor at application thicknesses between 4 mm and 30 mm. It exhibits excellent resistance to high pedestrian traffic and point loads such as wheelchairs. Its 28-day compressive strength is > 30 N/mm² and its bending strength is > 7 N/mm².

MICROFLOOR MB 1004 MFB (Industrial Heavy-Duty Fluid Micro Concrete)

It is the industrial monster formulated for areas with heavy loads and intense vehicle traffic, such as factory production areas, logistics warehouses, aircraft hangars, and indoor and outdoor parking lots. When applied between 4 mm and 15 mm thicknesses, it offers superior surface hardness against wheel friction and mechanical shocks. Its dust-free crystal matrix structure fully meets the sterile environment conditions sought in facilities. Its 28-day compressive strength reaches aggressive performance values such as > 40 N/mm² and its bending strength reaches > 9 N/mm².

4. Why Should Micro Concrete Be Preferred? What Are Its Advantages Over Traditional Systems?

Micro concrete is not only an aesthetic trend in modern architecture and engineering projects, but also a functional solution that optimizes the budget, time, and labor equation at construction sites. When compared with classic floor coating materials such as ceramic, marble, parquet, and traditional epoxy, its standout unique advantages are as follows:

• Ease of Application Solving the Master Craftsman Crisis

The difficulty of finding qualified technical master craftsmen, which is the biggest problem of construction sites today, ceases to be a barrier with micro concrete. While the pool of master craftsmen capable of millimeter-level mitering and joint workmanship in traditional coatings is narrowing, the self-leveling capability of the Dolphinfix MicroFloor series reduces the error margin of application teams to zero and increases application speed 5-fold on a square meter basis.

• Seamless and Uninterrupted Monolithic Structure

The weakest point of piece-based materials such as ceramic and marble is the joint lines that get dirty, darken, and impair aesthetics over time. Micro concrete creates a single-piece (monolithic) surface without joints in the area where it is poured. This continuous structure adds a visual width and modern depth to spaces.

• Bacteria, Mold, and Moisture Resistance (Casein-Free Formula)

Unlike standard floor chemicals, the formulation of Dolphinfix micro concretes contains no casein, protein, or organic starch. Thanks to this, it can never breed bacteria, fungi, or mold even in humid environments. It fully meets the antibacterial and sterile flooring specifications required for hospitals, food production facilities, and pharmaceutical warehouses.

• Flawless Compatibility with Underfloor Heating Systems

Its thermal conductivity coefficient is quite high. When applied over underfloor heating systems, it does not block heat transfer; it provides energy savings by spreading heat quickly and homogeneously to the surface, and does not crack due to thermal shocks.

• Low Section Thickness and Structural Lightness

While traditional 5-10 cm thick concrete screeds place tons of static load on buildings, micro concrete offers the same (or higher) strength at a thickness of only 4-15 mm. Thanks to its feature of being applied over existing floors without breaking them, it completely eliminates rubble, excavation, and static load costs.

5. Where Is Micro Concrete Used? Is It Suitable Only for Interiors?

One of the most frequently asked questions about micro concrete technology is whether this material is a decorative element specific only to interior designs. Thanks to improved polymer binders and mineral matrix structure, the Dolphinfix MicroFloor series is used safely with high performance not only in interior stabilization, but also in outdoor projects open to atmospheric conditions where temperature differences are aggressive.

The modified flexible structure and high adhesion capability of the material make its areas of use almost limitless. Based on the character of your project, the primary employment areas of micro concrete are as follows:

Residential and Commercial Building Applications

Micro concrete is an indispensable instrument for professionals who want to create a sense of width, continuity, and minimalism in architectural designs. The seamless integrity, aesthetics, and functionality it offers indoors stand out in the following areas:

• Homes and Villas

It offers a modern industrial elegance in all living areas, especially living rooms, open kitchens, corridors, and foyers. It increases in-home comfort thanks to its full compatibility with underfloor heating systems.

• Hotel and Hospitality Sector

It creates both stylish and extremely practical-to-clean floors in hotel lobbies, reception areas, corridors, and modern hotel room floors exposed to the abrasive effects of heavy pedestrian traffic and luggage wheels.

• Restaurants, Cafes, and Concept Stores

It strengthens brand image with color alternatives that support corporate identity and architectural concept. It is fully resistant to food or beverage stains that may be spilled on it against protective varnish systems.

• Office Complexes and Showrooms

In large-scale commercial areas, automotive showrooms, or modern offices, it promises a natural, elite floor architecture, leaving heavy ceramic workmanship and the artificial plastic look of epoxy behind.

Industrial, Sterile, and Outdoor Areas

Formulated according to sudden changes in air temperature, freeze-thaw cycles, and heavy mechanical load classes, our MICROFLOOR MB 1004 MFB industrial-type system offers the following solutions in the industry's most challenging sites:

• Factory Production Areas and Warehouses

It offers a stable body that does not wear down or peel off on production lines where heavy vehicle, forklift, and pallet truck traffic, and friction and point shock loads are never lacking.

• Logistics Centers and Hangars

By ensuring large areas are covered seamlessly and quickly, it enables logistics flow to continue with smooth and vibration-free wheel movements.

• Hospitals, Laboratories, and Food Production Facilities

It is antibacterial and antimicrobial thanks to its protein- and casein-free structure. It fully meets specifications in areas where sterilization is vital with its non-dusting surface texture and resistance to cleaning chemicals.

• Indoor and Outdoor Parking Lots

It does not lose its strength against exhaust gases, engine oils, wheel frictions, and aggressive weather conditions such as rain, snow, and frost outdoors; it offers safe driving comfort with anti-slip additives.

• Terraces, Balconies, and Walkways

It shows full resistance to UV rays outdoors; it allows the construction of modern walkways and landscape floors in the outdoor areas of buildings without yellowing, fading, or cracking.

6. Can Micro Concrete Be Made in Colored and Different Designs?

Yes, absolutely possible! Micro concrete projects are not condemned to the monotony and industrial coldness of standard gray tones. Dolphinfix production technology has the flexibility to produce the material with special color pigmentations depending on specification requests, corporate identity lines, and architectural concepts.

This flexible and transformable structure of the material brings the following advantages in the design world:

• Wide Color Palette

Production can be made in a very wide color spectrum ranging from natural beige tones to warm earth colors, anthracite and black to pastel architectural tones. Thanks to this, the floor achieves complete harmony with the furniture, wall, and lighting elements in the space.

• Design and Matrix Freedom

While the micro concrete is being applied, an artistic character that is living, natural, and has marbled movements can be imparted to the floor using surface finishing techniques (different trowel strokes, light antiqued effects, or completely smooth satin finishes).

• Flexible Solution for Architects and Contractors

Especially in luxury hotel projects, brand showrooms, modern villa designs, and concept restaurants, the imagination of architects is not restricted. For professionals who do not want to be stuck in the molds of standard coating materials, Dolphinfix color alternatives maximize design freedom and provide full control over the project.

7. What Are the International Standards of Micro Concrete Products?

The accuracy of technical declarations of industrial, architectural, and commercial floor coating systems must be certified with internationally accepted test methodologies. For a floor to be safe, long-lasting, and compliant with specifications, it must meet certain standards.

The Dolphinfix MicroFloor series has been tested and certified according to the following critical European standards that determine floor performance characteristics and stable matrix structure:

• SS 92 35 07 Standard (Fluidity and Rheology Control)

This standard measures the self-leveling capability of fluid cement-based mortars, spread diameter, and how homogeneous a flow they exhibit after mixing without undergoing segregation (separation/settling of components of the material). Dolphinfix products have passed this test with flying colors, technically proving that they will create a wave-free and flawless spreading floor on the construction site.

• SS 92 35 19 Standard (Surface Adhesion and Bond Strength)

The biggest risk in floor coatings is the material separating from the sub-concrete, cracking, or lifting over time. This standard measures the adhesion of micro concrete to the sub-layer, namely pull-off strength, down to the millimeter. Having high polymer modification, the Dolphinfix series has documented that it establishes a monolithic (integrated) bond with the surface it is applied to by showing adhesion values far above standards in these tests.

• EN 13813 Standard (Cementitious Screed Materials)

It is the main umbrella standard determining the performance classes of floor mortars across Europe (Compressive strength – Class C, Bending strength – Class F, Abrasion resistance – Class A). Dolphinfix MicroFloor products possess high performance declarations within the industrial class under this standard.

8. Step-by-Step Micro Concrete Application Methodology (System Integration)

Achieving a flawless result in micro concrete application is a chain of floor engineering. When the correct system components are followed sequentially, this application is completed with the highest success rate. The step-by-step application methodology that solves the master craftsman crisis at construction sites and minimizes the margin of error is as follows:

Step 1: Subfloor Analysis and Mechanical Cleaning

The main body to be applied (existing screed, concrete, or old coating) must be absolutely dry, hard, and structurally stable. Loose parts, cement slurry, old paints, oil, and grease residues prevent the material from clinging to the surface.

For this reason, the surface must be abraded using mechanical grinding or sanding machines and its pores must be opened. Micro dust remaining on the surface after cleaning must be completely sucked up and removed from the environment using industrial vacuum systems.

Step 2: Floor Preparation, Filling, and Repair

Deep holes, segregation (honeycomb) voids, cracks, or elevation differences located on the floor must not be filled directly with top-coat micro concrete. Such structural defects must be filled with MICROFLOOR RM 1000 MRM floor repair mortar, which does not undergo shrinkage and offers high mechanical resistance. Depending on the condition of the cracks, epoxy injection or mesh reinforcement should be done if necessary to bring the subfloor to a completely smooth and stable level.

Step 3: Correct Primer Selection and Application

The priming step is the insurance of the system to ensure that the micro concrete adheres to the sub-layer like bone and that air inside the mortar does not rise to the surface during pouring to form pinhole pores. Dolphinfix offers two different primer concepts depending on the surface characteristic:

Scenario A – Glossy and Non-Absorbent Surfaces (Tile, Marble, Ceramic, Gross Concrete)

If application is to be made over such surfaces without breaking the old material, single-component and acrylic-based Dolphinfix PAR 721 Glossy Surfaces Screed Primer should be used. It maximizes mechanical adhesion by creating a rough texture on glossy surfaces with its specially filled formula. (Consumption: 150 – 250 g/m²)

Scenario B – Absorbent Surfaces (Gypsum, Aerated Concrete, Raw Plaster, Porous Screed)

To balance the high absorbency of the subfloor and prevent the micro concrete from cracking by suddenly losing its mixing water, copolymer acrylic-based Dolphinfix EMC 720 Absorbent Surfaces Screed Primer should be applied. (Consumption: 200 – 400 g/m²)

Step 4: Precise Mixing and Homogenization

Millimeter-level loyalty to the water/powder ratio is mandatory in micro concrete applications. Excess water decreases the strength of the material, while too little water impairs fluidity. A 25 kg bag of MICROFLOOR MB 1003 or 1004 is slowly emptied into a clean container containing 20% (5 liters) clean and cold water.

It is mixed continuously for at least 2-3 minutes using a low-speed mixer at 400-600 rpm until a completely homogeneous liquid without lumps is obtained. The mortar is rested for 2 minutes for micro air bubbles inside it to subside, and is mixed for another 30 seconds before pouring to optimize its rheology.

Step 5: Pouring, Leveling, and Spike Roller Operation

The prepared fluid mortar is poured onto the floor in a continuous and homogeneous line. The material is spread onto the surface with the help of a leveling rake (tooth rake) or steel trowel adjusted according to the desired application thickness.

While the material settles with its self-leveling feature, it must be rolled with a spike roller in cross directions to burst air bubbles trapped inside the mortar, prevent pinholes, and flawlessly fuse joint locations. During application, it should be paid attention that the ambient temperature is between +5°C and +30°C and there is no air flow (draft) in the area.

9. Critical Post-Application Processes: Protective Varnish (Sealing) and Curing Times

The pouring of the micro concrete mortar and the completion of the spike roller operation are the first stages of the floor engineering process. To obtain long-term mechanical performance, stain resistance, and aesthetic stability from the system, correct management of chemical curing and sealing processes post-pour is of vital importance.

Why Is Protective Varnish (Sealer) Application Mandatory After Micro Concrete?

By nature of all cement-based matrices, as the mixing water inside the mortar completes its hydration (curing) reaction and evaporates, it leaves microscopic pores and capillary channels on the surface. If the micro concrete floor is left "bare" in this way, it remains completely vulnerable to external factors.

• Stain and Chemical Resistance

Coffee, oil, wine, acids, detergents, or engine oils that may spill onto the surface in daily use or industrial areas seep into these pores, causing impossible-to-clean stains and discoloration.

• Prevention of Dusting

Preventing cement particles from dusting at the micronized level due to friction over time is only possible by locking the surface with a binding layer.

• Liquid Impermeability and Hygiene

Protective varnish creates a smooth shield that is liquid-proof, moisture-resistant, and easy to clean by completely filling microscopic voids on the surface.

Dolphinfix System Recommendation: After the micro concrete is completely dry, applying a polyurethane- or acrylic-based protective sealing varnish (topcoat/sealer) on top is mandatory. While this varnish layer imparts water repellency and chemical resistance to the floor, it takes the visual quality and color vibrancy of your project to the peak with matte, satin, or gloss finish options.

How Do Drying Times and the Schedule for Opening to Traffic Work?

The Dolphinfix MicroFloor series is formulated with special fast-curing hydraulic binders to radically reduce "waiting times", which is the biggest cost item at construction sites. When making your project management plan, you should base it on the following schedule:

• Opening to Pedestrian Traffic (2 – 4 Hours)

Just 2 to 4 hours after the application is finished, the floor can be walked on with light steps. Thanks to this, other construction site disciplines (painting, electricity, etc.) can enter the site without disrupting the project.

Varnish (Sealing) Application Time (1 – 3 Days)

Depending on ambient temperature, relative humidity, and cross-section thickness, 24 to 72 hours should be waited for the structural moisture within the body of the micro concrete to be thrown out completely. After moisture measurement is done, transition is made to protective varnish application.

• Light Vehicle Traffic (24 Hours)

In industrial-type MICROFLOOR MB 1004 MFB applications, passage of light-wheeled vehicles and pallet trucks can be allowed 24 hours after pouring.

• Full Mechanical and Chemical Curing (7 Days)

The material attains its final crystal matrix structure at the end of the 7th day. Heavy forklift traffic, shock loads, and aggressive chemical cleaning processes should be initiated after this period.

Can a Different Coating Be Made Over Micro Concrete in Future Years?

Yes, it can be done very easily. Thanks to their high compressive strengths and self-leveling structures, micro concrete floors serve as great load-bearing sub-floors for future transformations as well.

If you want to change the design concept of the space in future years, turn an industrial area into an office, or use a completely different material; there is no need to break, dismantle, or deal with excavation noise of the existing micro concrete.

Thanks to the smoothness and high adhesion capability offered by the floor, you can directly execute epoxy, polyurethane coating, laminated parquet, carpet, or ceramic applications over the existing micro concrete layer without making any structural renovations. This feature provides a huge budget and flexibility advantage to property owners and businesses in the long run.

10. Golden Rules for Correct Product Selection and Flawless Result

Minimizing construction site risks in micro concrete applications, turning the master craftsman crisis into an advantage, and building long-lasting floors requires an engineering discipline. In line with technical data tested in Dolphinfix laboratories and our field experience, the golden rules you should take as a guide for a flawless delivery are as follows:

• Right Product for the Right Function

Never leave standard sublayer mortars sold in the market under the name of "mercury screed" or "leveling screed" exposed as a top-coat decorative floor. Depending on the load class of your project, prefer the MICROFLOOR MB 1003 series in residential and commercial areas, and the MICROFLOOR MB 1004 series in heavy industrial areas.

• Lock the Infrastructure with the Correct Primer

Never compromise on the priming step to ensure flawless adhesion and prevent the formation of pinhole pores on the surface. Create the insurance of the system by using Dolphinfix PAR 721 on glossy surfaces (ceramic, marble) and Dolphinfix EMC 720 on absorbent surfaces (raw screed, concrete).

• Stick to the Water Ratio and Rheology

Do not add water during mixing based on word-of-mouth information. Comply millimetrically with the water ratio stated in the TDS formulation. Too much water causes cracking, flaking, and loss of strength on the surface; too little water causes the material to lose its self-leveling capability.

• Control Air Flow and Temperature

Do not expose the environment directly to wind, drafts, and direct sunlight during application and for the first 24 hours after pouring. Sudden air currents lead to irregular drying of the material and stress cracks.

• Do Not Neglect the Sealing Varnish

To ensure micro concrete floors do not stain, do not pass liquids, and maintain their stable structure against chemicals, definitely apply the polyurethane- or acrylic-based protective sealing varnish (sealer) following the curing process.

Contact Us for the Amount of Product You Need!

Dolphinfix offers reliable supply and technical support in chemical construction products, concrete solutions, insulation systems, and special mortar groups, ranging from packaging options starting from 1 kg to pallet, tonnage, and truck-based industrial deliveries. For detailed information and quotes, you can visit www.dolphinfix.com.tr or contact our sales representatives.

📞(0212) 945 00 59

Get a quote for bulk purchases