🌐 English ▾
📞 Customer Line 24/7539 303 00 72
🌐 English ▾
Home›Blog›Screed Applications in the Construction Sector: De...

Screed Applications in the Construction Sector: Dead Load Hazard and Lightweight Screed Solutions

19.05.2026 Screed Applications in the Construction Sector: Dead Load Hazard and Lightweight Screed Solutions

Dolphinfix is a strong brand offering professional solutions in the fields of construction chemicals, concrete solutions, historical artifact restoration mortars, and heat, water, and sound insulation systems. With flexible sales options ranging from 1 kg to truckloads, a wide product range, and the advantage of fast supply, it provides reliable solutions from individual applications to large-scale construction site and industrial projects.

The most critical stage of the finishing phase, which begins with the completion of the structural shell in construction projects, is undoubtedly screed pouring. The lifespan of an aesthetic floor covering (parquet, ceramic, epoxy, etc.) directly depends on the quality and technical characteristics of the screed applied underneath it. However, in modern engineering, screed is not just a floor leveling tool; it is a strategic layer that determines the structural statics, earthquake safety, and energy efficiency of the building.

In this article, we will detail the massive "dead load" risks that traditional screed brings to the structure, the insulation parameters, and the next-generation lightweight screed solutions we offer as Dolphinfix.

What is Floor Screed? What Are Its Main Functions?

Screed is the layer poured onto finished reinforced concrete surfaces to level the floor, bring it to the desired level (grade), and prepare a smooth base for the final coat covering. However, the duties of screed are not limited to these.

Smoothness and Leveling

It eliminates irregularities in the reinforced concrete slab, creating a leveled floor.

Load Distribution

It evenly distributes live and dead loads coming onto the floor to the reinforced concrete surface, extending the lifespan of the structure.

Protecting Insulation Layers

It protects barriers that provide sound and thermal insulation between floors against physical impacts.

Concealing Installations

It traps underfloor heating pipes, electrical, and water installations safely beneath the floor.

The Invisible Danger of Screed: Dead Load and Earthquake Risk in Buildings

Although screed is seen as a "simple filling material" in the construction sector, it is one of the heaviest loads placed on the building in static calculations. Traditional sand-cement mixture screeds create tons of weight in our buildings.

Screed Weight Analysis: How Do We Carry Tons of Load?

We generally observe that screed thickness in residences is applied around 10 cm due to level differences. The static cost of this situation is as follows.

Traditional Sand-Cement Screed

  • Weight per M²: The weight of 1 m² of screed poured at a standard 5 cm thickness is approximately 100 kg. The weight of 1 m³ (1000 liters) of screed is calculated as an average of 2000 kg, meaning 2 tons.
  • Apartment-Based Calculation: When a 10 cm screed thickness is applied in a 100 m² apartment, the load added to the building becomes exactly 20,000 kg (20 Tons).
  • Disaster Across the Building: In an apartment building with 10 floors and 4 apartments on each floor, the dead load added to the building solely due to the 10 cm screed pour can reach 800 tons.

Next-Generation Lightweight Screed Solution: BORPER FLOOR 1800 BTŞ

BORPER FLOOR 1800 BTŞ is a next-generation lightweight screed solution developed to solve the weight problem of traditional screed.

BORPER FLOOR 1800 BTŞ Weight Analysis

  • Weight per M²: The weight of 1 m² of screed poured at a standard 5 cm thickness is approximately 25 kg. The weight of 1 m³ (1000 liters) of screed is calculated as an average of 500 kg.
  • Apartment-Based Calculation: When a 10 cm screed thickness is applied in a 100 m² apartment, the load added to the building becomes exactly 5,000 kg (5 Tons).
  • Across the Building: In an apartment building with 10 floors and 4 apartments on each floor, the dead load added to the building solely due to the 10 cm screed pour can reach 200 tons.

Gain with Next-Generation Lightweight Screed

  • In a 40-apartment building where sand-cement screed is used, the total weight is approximately 800 tons.
  • In the same building where screed made with the New Generation BORPER FLOOR 1800 BTŞ is used, the total weight is approximately 200 tons.
  • The difference means a load reduction of approximately 600 tons. Thus, our structure will carry 600 tons less load.

Why Is It Dangerous?

In the event of a possible earthquake, the lateral forces acting on the structure are directly proportional to the total mass of the structure. The more dead load your building carries, the more the destructive effect of the earthquake increases. As Dolphinfix, we produce technological solutions that will relieve your building of these tons of load.

Advantages of the Next-Generation Lightweight Screed Solution: BORPER FLOOR 1800 BTŞ

Developed against the weight and insulation weakness of traditional screed, BORPER FLOOR 1800 BTŞ – Heat, Sound, and Fire Insulation Leveling Screed is changing the balance in the industry. This special cement- and perlite-based mixture lightens your building while taking comfort to the maximum level.

Maximum Lightness

It reduces the dead load in the building by rates reaching up to 300%. By protecting the statics of your building, it makes a direct contribution to earthquake safety.

Superior Thermal Insulation

It provides energy efficiency with its T1 class thermal conductivity coefficient. It lowers heating costs.

Sound Insulation

It minimizes neighbor noise by blocking inter-floor impact sound at the 58-68 dB level.

Fire Safety

It is an A1 class non-combustible material. Unlike EPS or XPS, it does not release toxic gases while burning and maintains its structural integrity even at 1200 degrees.

Installation Compatibility

Thanks to its lightweight and fluid structure, it perfectly fills the spaces between pipes in underfloor heating systems and transmits heat quickly.

Pre-Screed Surface Preparation and Adhesion Promoters

A perfect screed is possible not only with the right material, but also with the right surface preparation. The failure of the screed to adhere fully to the floor (loss of adhesion) causes cracks and hollow sound formation over time.

Primer Solutions for Glossy and Absorbent Surfaces

PAR 721 – Glossy Surface Screed Primer

It is used to prevent the screed from sliding and lifting on non-porous surfaces such as tiles, marble, or exposed concrete. It removes the gloss of the surface and creates a rough bond.

EMC 720 – Absorbent Surface Screed Primer

It is used on surfaces with high absorbency, such as autoclaved aerated concrete or old concrete, to prevent the screed water from being suddenly absorbed and cracking.

Under-Screed Heat and Sound Insulation: 1970 – BRONZ Barrier

If an extra layer of comfort is desired under the screed, the 1970 – BRONZ Heat and Sound Insulation Barrier is indispensable. This 14-16 mm thick underlay is laid freely before the screed is poured. While cutting off the cold and noise coming from the floor below, it allows the screed layer to work on an elastic bed.

Reinforcement for Industrial Areas: KUVARS YSK 810

in areas with heavy traffic such as parking lots, factories, or warehouses, the abrasion resistance of the screed may remain insufficient. In this case, KUVARS YSK 810 – Surface Hardener, applied onto the fresh screed, protects the floor like armor against oils and wear. It prevents dust generation and provides an aesthetic appearance.

Technical Summary in Screed Application: What Should an Ideal Screed Be Like?

There are 4 main criteria that determine the success of a good screed application.

Crack Resistance

Appropriate dosage and joint cutting (including styrofoam application) must be performed.

Adhesion

A primer suitable for the surface (PAR 721 or EMC 720) must definitely be used.

Strength

The correct compressive strength must be selected according to the load it will bear.

Dryness

For the final coat covering (especially parquet), it must be waited for the moisture rate to drop below 2%.

Conclusion: Lighten Your Building, Secure the Future

Screed is the invisible hero of a structure. Choosing the wrong screed causes even the most luxurious floor covering to blister or crack over time. By using BORPER FLOOR 1800 BTŞ and BORPER 1810 Thermal Insulation Plaster, you can relieve your structure from dead loads and build a safer, insulated, and more economical living space.

Contact Us for the Quantity of Product You Need!

Dolphinfix offers reliable supply and technical support in construction chemicals, concrete solutions, insulation systems, and special mortar groups, ranging from packaging options starting from 1 kg to pallet, tonnage, and truck-based industrial deliveries. For detailed information and quotes, you can visit www.dolphinfix.com.tr or contact our sales representatives.

📞(0212) 945 00 59

Get a quote for bulk purchases